What the symptoms usually point to
- Fresh-food side warm, freezer cold: cold air is made behind the freezer panel and blown across. A frosted evaporator coil or a stopped evaporator fan cuts that off.
- Both sides warm: look at the condenser fan, the start relay on the compressor, or a coil underneath so dusty it cannot shed heat.
- Water pooling under the drawers: the defrost drain has frozen or clogged, so melt water spills inside the cabinet.
- No ice: a kinked supply line, a clogged inlet valve screen, or a freezer that is not cold enough for the ice maker to cycle.
- Clicking every few minutes, no cooling: the compressor is trying to start and the overload keeps cutting it out.
Checks that are safe before the visit
Look at the thermostat first; a bumped dial explains more calls than you would think. Close a sheet of paper in the door and pull it: if it slides out with no drag, the gasket is not sealing. Move food away from the vents between the two compartments. Then pull off the kick plate and look at the condenser coil. Built-in and cabinet-depth refrigerators in remodelled San Carlos kitchens often have very little space around them, and a dusty coil in a tight opening makes the compressor run long and hot.
If the back wall of the freezer is a solid sheet of frost, the defrost system is the likely suspect. Thawing it with the doors open buys a few days, but the fault returns until the failed part is replaced.
What the repair business checks
A proper diagnosis measures temperatures at the coils, tests the defrost heater, sensor and control board, and listens to the compressor and both fans. Fan motors, start relays, defrost sensors and door gaskets are common single-part repairs. Sealed-system work, such as a refrigerant leak or a compressor, is a different scale of job; on an older refrigerator a straight answer about whether it is worth doing is part of a good visit.
Keep a cooler and ice nearby. Food held above 40°F for more than about two hours should be thrown out, according to US food safety guidance.
Common questions
Why is my fridge warm but my freezer still cold?
Most often the evaporator coil has frosted over or its fan has stopped. Cold air is made behind the freezer panel and blown across to the fresh-food side, so when that airflow stops, the fridge warms while the freezer stays cold. Check that food is not blocking the vents between the compartments. It is usually a repairable fault, such as a fan motor or defrost part, rather than a failed compressor.
Is it worth fixing a refrigerator that is ten years old?
Often, yes, if the problem is a fan, relay, defrost sensor or door gasket, since those are single-part repairs. A National Association of Home Builders study puts a refrigerator’s typical life at about 13 years, so a ten-year-old fridge is getting close. If the sealed system or compressor has failed, replacing it usually makes more sense. Ask for the diagnosis and the full price before you decide either way.
Should I unplug the fridge before the technician comes?
Usually not. Leave it running so the fault can be seen and measured when the technician arrives; temperatures at the coils, fan sounds and compressor behaviour all help the diagnosis. Unplug it only if a breaker trips, you smell burning, or the freezer’s back wall is a solid sheet of frost that needs to thaw. Keep a cooler and ice nearby, and keep the doors closed meanwhile.